Powering

Motor & Drive Control

Your motors run flat out when the process only needs part of the flow

A pump throttled against a valve, a fan damped down, a conveyor slamming to full speed on every start, all of it burns energy and wears out the mechanical end of the system. The fix is speed matched to demand, and a drive specified against the whole electrical chain rather than picked off a power rating.

Applies to
Pumps Fans & blowers Conveyors Compressors Mixers & agitators HVAC plant
Authorised Danfoss drive partner Harmonics and cable length checked before order Obsolete drive replacement supported
Danfoss variable speed drives installed in an industrial switchboard

The Four Loads That Drive Most of the Saving

Where speed control pays back fastest, and the question that decides how it should be controlled.

Pump flow gauge

Pumps

Throttling against a valve wastes most of the energy the motor draws. Speed control matches flow to demand and takes the pressure spikes out of the system.

VSD closed loop PID on pressure Sleep / boost Multi-pump cascade
Decides it: Is flow being controlled by a valve or a bypass today?
Energy trend line

Fans & Blowers

Variable-torque loads where a small speed reduction returns a large power reduction, usually the fastest payback on site.

Variable torque profile Damper removal Automatic energy optimisation
Decides it: Are dampers or inlet vanes doing the throttling?
Conveyor with package

Conveyors & Materials Handling

Controlled ramps stop belt slip and gearbox shock loading, and let multiple drives share load along a long run.

Ramped start / stop Load sharing Brake control Encoder feedback
Decides it: Is the belt loaded on start, and are drives mechanically coupled?
Duty cycle clock

Compressors & Process Machinery

High-inertia and constant-torque duty where inrush, restart limits and thermal duty decide the topology, not just the kW.

Constant torque Soft start Regenerative braking Safe Torque Off
Decides it: How many starts per hour, and does the load drive the motor on stop?

Three Ways to Start and Control a Motor

Not every motor needs a drive. Choosing the cheapest adequate method is part of the specification.

Method
What it does
When to use it
Direct online (DOL)
Full voltage applied immediately, simplest and lowest cost.
Small, low-inertia loads where inrush current and mechanical shock are not a concern.
Soft starter
Ramps voltage on start, reducing inrush and mechanical shock.
Smooth starting is needed but speed does not have to vary during the run.
Variable speed drive
Full speed and torque control throughout operation, plus motor protection and diagnostics.
Energy saving, process control, high start frequency, or protection of the driven equipment.

Sizing is only half of it. Cable length, motor insulation, harmonic exposure and braking duty decide whether the drive needs filtering, a brake chopper or a different topology altogether, nine checks we run before quoting.

What Sites Get Out of It

The outcomes that matter on site.

Downward energy trend

Energy Drawn to Match Demand

Variable-torque loads follow the affinity laws, modest speed reductions on pumps and fans cut power draw sharply.

Uptime clock

Less Mechanical Wear, Fewer Stoppages

Ramped starts protect belts, couplings and gearboxes from the shock loading that shortens their life.

Process control gauge

Tighter Process Control

Closed-loop speed on pressure, flow or level holds the setpoint instead of hunting between on and off.

Compliance shield with tick

Compliance and Safety Built In

Safe Torque Off to SIL3, harmonic mitigation and EMC filtering specified against your site requirements.

The Brand Behind This Application

Danfoss, a drive tier for every duty, from OEM panel to liquid-cooled

We are an authorised Danfoss drive partner supplying the full VLT, VACON and iC range, plus the VLT MCD soft starter family and line-side and output filtering. One brand across every tier means the control philosophy, fieldbus and spares strategy stay consistent as the site grows.

VLT VACON iC2 iC7 VLT MCD soft starters Filters & braking
Danfoss iC7 variable speed drive

Tell Us What the Motor Has to Do

Send the motor nameplate, the load type, cable run length and how it is controlled today. Our technical team will confirm the right method and the right Danfoss package before you buy.

Motor nameplate, kW, voltage, current, insulation class
Load type and duty, variable or constant torque, starts per hour
Cable run length between drive and motor
How the motor is started and controlled today
Any harmonic, EMC or zone classification requirements