What Is a VSD? Types of Variable Speed Drives and Where Each One Fits

Published by Pacific Automation on 17th Nov 2026

A pump running flat out while a valve throttles back the flow. A fan stuck at full speed regardless of building demand. A conveyor that slams to full speed on every start. These are the costly mechanical and energy problems a variable speed drive (VSD) is built to solve.

 

While older drive platforms have long served as industry workhorses, modern industrial systems require smarter motor control, built-in cybersecurity, and long-term adaptability. Enter the next-generation Danfoss iC7 series, a unified, future-ready drive platform designed to replace legacy architectures across heavy industry, water utilities, and commercial building services.


In this guide, we explain what a VSD is, how it works, and how the Danfoss iC7 platform stacks up across pumps, fans, conveyors, and compressors.

What Is a VSD?

A VSD, or variable speed drive, is an electronic device that controls the speed and torque of an AC electric motor. Instead of running a motor at a fixed speed from the mains supply, a VSD lets you run it at exactly the speed the process needs.


In electrical terms, a VSD sits between the power supply and the motor. It takes the fixed-frequency mains supply and converts it into a variable-frequency output, which sets how fast the motor turns

How Does a VSD Work?

A standard AC motor's speed is set by the frequency of its supply. In Australia that is 50 Hz, so a motor connected directly to the mains runs at one speed.

 

A VSD changes that frequency in three stages:
 
  1. Rectifier: converts the incoming AC supply to DC.
  2. DC link: smooths and stores the DC power.
  3. Inverter: switches the DC back to AC at whatever frequency and voltage the motor needs.
Lower the frequency and the motor slows down. Raise it and the motor speeds up. The drive also ramps the motor up and down smoothly, which reduces inrush current and mechanical stress on belts, gearboxes and couplings.

VSD vs VFD: Is There a Difference?

No. VSD (variable speed drive) and VFD (variable frequency drive) describe the same device. VSD is the more common term in Australia and the UK, while VFD is widely used in the US. You will also see the terms AC drive, inverter and adjustable speed drive used in the same way.

Why Use a Variable Speed Drive?

Matching motor speed to the load delivers three main outcomes:

Energy savings. On pumps and fans, power draw falls sharply as speed drops. Running a centrifugal pump or fan at 80% speed can cut its power use roughly in half, compared with running at full speed and throttling with a valve or damper.

Process control. Hold a set pressure, flow, level or temperature automatically rather than relying on manual adjustment.

Equipment protection. Soft ramping, current limiting and built-in motor protection reduce wear and help prevent unplanned downtime.

Types of Variable Speed Drives

Not every VSD is built for the same job. Drives are generally grouped by the application they are designed for, their power range and how they are mounted and cooled. Here is how the main types line up across the Danfoss range.

The New Standard: The Danfoss iC7 Platform

Rather than treating every drive as a generic frequency converter, modern system design relies on platform flexibility, native functional safety, and software-defined adaptability. The Danfoss iC7 is Danfoss’s flagship, next-generation drive platform built to handle everything from standard pumps and fans to heavy industrial automation.

Key future-proofing benefits built into the iC7 platform include:

  • Licence-Key Fieldbuses: Change or upgrade communication protocols (PROFINET, EtherNet/IP, EtherCAT, Modbus TCP, and OPC UA) via a software licence key without needing to swap physical option cards.
  • Advanced Functional Safety: Safe Torque Off (STO) and Safe Stop 1 (SS1-t) to SIL3 / PL e come standard, eliminating the need for external safety contactors.
  • Universal Motor Control: Seamless open- and closed-loop control of induction, permanent magnet, and synchronous reluctance motors.
  • Native Cybersecurity: Built-in hardware-based cybersecurity features to protect operational networks.

Here is how the iC7 and its specialized variants align across applications:

General Purpose and Automation: Danfoss iC7-Automation

The iC7-Automation is a highly configurable, core drive platform covering 0.37 to 710 kW as a frequency converter, scaling up to 2,700 kW with system modules. It handles demanding constant- and variable-torque loads including heavy conveyors, hoists, compressors, multi-drive systems, food and beverage lines, and high-spec panel builds.

HVAC Building Services: Danfoss iC7-HVAC

Designed specifically for commercial building services, the iC7-HVAC brings next-generation intelligence to air handling units, chillers, cooling towers, and supply and exhaust fans. It incorporates dedicated HVAC functionality, advanced building management system (BMS) integration, and energy-optimisation profiles for modern smart buildings.

Water and Wastewater: Danfoss iC7-AQUA

Designed specifically for commercial building services, the iC7-HVAC brings next-generation intelligence to air handling units, chillers, cooling towers, and supply and exhaust fans. It incorporates dedicated HVAC functionality, advanced building management system (BMS) integration, and energy-optimisation profiles for modern smart buildings.

Ultra-Low Harmonic and AFE Solutions (From Wall-Mount to High Power)

For installations operating on weak grid supplies, remote generator networks, or sites with strict network compliance codes (such as IEEE-519), the Danfoss iC7 platform integrates Ultra-Low Harmonic (ULH) technology across both compact wall-mount drives and high-power enclosed drive solutions (via Active Front End modules).

By replacing standard diode rectifiers with active switching stages and integrated LCL filtering, these iC7 drives keep total harmonic distortion (THDi) below 3–5% right out of the box—eliminating the need for external harmonic filters, oversizing transformers, or risking nuisance tripping on generator-backed sites. For high-power and regenerative applications, iC7 Active Front End (AFE) system modules also allow braking energy to be fed cleanly back into the mains supply.

General Purpose and Compact Drives: Danfoss iC2

General purpose drives handle simple speed control on smaller motors. They suit panel builders, OEMs, maintenance replacements and straightforward variable-torque loads like small pumps, fans and light conveyors.

The Danfoss iC2 Micro Drive is a compact, cost-effective option for these applications, with a small footprint for tight control panels.

Proven Industry Standards: Danfoss VLT and VACON Drives

Alongside the next-generation iC7 platform, we continue to supply and support the full Danfoss VLT and VACON drive ranges—which remain in active production and serve as trusted standards across Australian mining, marine, water, and building services sites.

Whether your facility standardises on the VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VACON 100, decentralised VACON 100X, or high-power VACON NXP/NXC systems, our engineering team supports both ongoing VLT/VACON deployments and new iC7 specifications.

Where VSDs Are Used: Pumps, Fans, Conveyors and Compressors

Pumps. Water and wastewater pump stations, mine dewatering, irrigation and desalination. VSDs hold pressure or flow on demand and cut energy use.

Fans and blowers. Ventilation, cooling towers and aeration blowers, where demand changes through the day.

Conveyors. Long-distance and overland conveyors in mining and materials handling, where soft starting and torque control protect belts and gearboxes.

Compressors. VSD air compressors match output to air demand instead of cycling between load and unload.

HVAC and chillers. Air handling units, chilled water pumps and cooling towers in commercial and industrial buildings.

VSD vs Soft Starter: Which Do You Need?

Both reduce inrush current and mechanical shock at start-up. The difference is what happens after the motor is running.

A soft starter ramps the voltage up during start-up, then the motor runs at full speed. It suits applications that need a smooth start but no speed control.

A VSD controls speed and torque throughout operation. If you need energy savings, process control or application-specific protection, a VSD is generally the better choice.

For soft starting, the Danfoss VLT MCD range covers a wide range of motor sizes.

Choosing the Right VSD for Your Site

Getting the drive right means looking at the whole electrical system, not just the motor. Before recommending a drive, our engineering team reviews:

  • Incoming supply capacity and short-circuit ratio (SCR)
  • Transformer or remote generator limitations
  • Motor insulation compatibility
  • Cable length and dv/dt risk
  • Harmonic distortion exposure and site compliance standards (such as IEEE-519)
  • Braking or regenerative requirements
  • Environmental conditions and physical footprints
  • Control philosophy and network communication requirements

Tackling Weak Supplies, Generators, and Harmonic Distortion

Harmonics, long motor cables, and weak electrical supplies are among the most common causes of nuisance tripping and premature equipment failure on industrial drive installations—particularly on remote sites operating on generator sets or unstable local grids.

To guarantee line-side integrity and protect sensitive site infrastructure, we engineer complete harmonic mitigation and power quality solutions tailored to your operational environment:

  • Active Front End (AFE) Topologies: Ideal for high-performance or regenerative applications on weak networks, AFE drives replace traditional diode rectifiers with active switching, driving total harmonic distortion (THDi) down to near-zero levels while feeding energy cleanly back into the supply.
  • Passive and Active Filtering: We specify and integrate precision passive harmonic filters, dv/dt filters, sine-wave filters, and common-mode chokes to safeguard motor insulation over long cable runs and ensure compliance with strict network codes.

Upgrading Existing Fleets or Migrating from Legacy Drives

Danfoss logo on a red background.

Both the Danfoss VLT and VACON drive series (including the VACON NXP and NXC platforms) remain in full, active production and continue to serve as proven industry workhorses across mining, water, and commercial facilities. However, when engineering a greenfield project or planning a long-term lifecycle upgrade, specifying the Danfoss iC7 ensures your site is built on Danfoss’s newest hardware, cybersecurity, and software-defined architecture.

At the same time, many industrial sites still run genuinely obsolete drives from older generations (such as legacy VLT 2800/5000/6000 units, VACON NXL/CX, or ageing ABB, Schneider, Allen-Bradley, and Siemens platforms) where spare parts are scarce and downtime risks are high.

Whether you are standardising new builds on the iC7 or replacing end-of-life third-party hardware, our team helps you plan a clean transition by:

  • Auditing existing drive fleets to separate active, supported models from genuinely obsolete units.
  • Mapping existing I/O, control wiring, and fieldbus communications to the iC7 architecture.
  • Verifying motor insulation and cable lengths to prevent harmonic or $dv/dt$ issues on upgraded systems.
  • Delivering a staged, low-risk migration path that minimises plant downtime.

Not sure where your current VLT drive sits in its lifecycle? Read our guide: Deciphering the Age of a Danfoss VLT Drive.

FAQ

What does a VSD do?

A VSD controls the speed and torque of an AC motor by changing the frequency and voltage of its power supply, so the motor runs only as fast as the process needs.

 

Is a VFD the same as a VSD?

Yes. Variable frequency drive (VFD) and variable speed drive (VSD) are two names for the same device.

 

Can a VSD run a three-phase motor from a single-phase supply?

Some drives accept a single-phase input and deliver a three-phase output, typically on smaller motors. The drive often needs to be derated, so check the specification for your motor size.

 

How much energy can a VSD save?

It depends on the application. The biggest savings are on pumps and fans, where reducing speed by 20% can cut power consumption by around half.