Bernstein AG, F1-ZSD Enabling Foot Switch, 2NO 1NC

Product Description
F1-ZSD
DGUV Approved Aluminium Foot Switch with Pressure Point, 1-Pedal, 1NC 2NO
Bernstein Foot Switches are suitable for high requirements in industrial applications.
• Existing mounting holes offer the possibility of screwing the foot switches to the base.
• Footswitch offers two enabling contacts, one signalling contact and is available both with and without detent.
1. Dynamic position detection is possible with the signal contact. Alternatively, a static position detection can be realised by means of a PNP output. In this way, it is possible to determine actuating position 1 - the OFF position of the enabling Contacts (actuator is not pressed) - or position 3 - the OFF position of the operating Contacts (actuator is fully pressed) - and make them directly available to the control system.
2. When the pedal is depressed to the pressure point, the two enabling contacts close. When the pedal is released, the enabling contacts open again.
3. If the pedal is depressed, i.e. beyond the pressure point, the release contacts open in a positively driven manner. For the application of an enabling device, the standards DIN EN ISO 12100 and DIN EN 60204-1, among others, must be observed.
The approved enabling foot switch is only available in the standard version without UN bonnet.
DGUV Approved Aluminium Foot Switch with Pressure Point, 1-Pedal, 1NC 2NO
Bernstein Foot Switches are suitable for high requirements in industrial applications.
• Existing mounting holes offer the possibility of screwing the foot switches to the base.
• Footswitch offers two enabling contacts, one signalling contact and is available both with and without detent.
1. Dynamic position detection is possible with the signal contact. Alternatively, a static position detection can be realised by means of a PNP output. In this way, it is possible to determine actuating position 1 - the OFF position of the enabling Contacts (actuator is not pressed) - or position 3 - the OFF position of the operating Contacts (actuator is fully pressed) - and make them directly available to the control system.
2. When the pedal is depressed to the pressure point, the two enabling contacts close. When the pedal is released, the enabling contacts open again.
3. If the pedal is depressed, i.e. beyond the pressure point, the release contacts open in a positively driven manner. For the application of an enabling device, the standards DIN EN ISO 12100 and DIN EN 60204-1, among others, must be observed.
The approved enabling foot switch is only available in the standard version without UN bonnet.
Downloads
Product Specifications
Manufacturer | Bernstein |
IP Rating | IP67 |
Entry Type | 1 x M20 |
Number of Pedals | 1 |
Pedal 1 Contact | 2NO 1NC |
Pedal 1 Contact Type | Slow |
Pedal 1 Stages | 3 Stage |
Protective Cover | No |
Manual Reset | No |
Safety Type | Enable Footswitch |
Pressure Point | 200N |