Bernstein F3-SU1ZA2ZDR/SU2ZD/SU1ZA2ZDR C Foot Switch

Product Description
F3-SU1ZA2ZDR/SU2ZD/SU1ZA2ZDR C
Foot switch metal; 3-pedal; left and right pedal: 3 NC/1 NO, middle pedal: 2 NC/2 NO, left and right pedal with safety catch and manual release
Suitable for high requirements in industrial applications. Existing mounting holes provide the option of screwing the foot switches to the base. Each foot switch is equipped with four rubber feet to prevent slipping. In the case of multi-pedal foot switches, crossbars prevent the unintentional simultaneous actuation of several pedals (versions without crossbars available on request). The foot levers are made of thermoPlastic. Foot switch with safety catch and manual release: Actuation of the pedal up to the pressure point: The working contact is closed, the working process is initiated. In an emergency situation, actuation beyond the resistance of the pressure point: The working contact is interrupted and locked, the working process is interrupted. Even if the pedal is not actuated, the lock remains in the OFF position in this phase. This reliably prevents an uncontrolled restart or a new start of moving machine parts. Unlocking: Only after the hazardous situation has been eliminated does manual unlocking (push button on the side of the housing) release the Contacts again. The work process can be restarted by pressing the pedal to the pressure point.
Foot switch metal; 3-pedal; left and right pedal: 3 NC/1 NO, middle pedal: 2 NC/2 NO, left and right pedal with safety catch and manual release
Suitable for high requirements in industrial applications. Existing mounting holes provide the option of screwing the foot switches to the base. Each foot switch is equipped with four rubber feet to prevent slipping. In the case of multi-pedal foot switches, crossbars prevent the unintentional simultaneous actuation of several pedals (versions without crossbars available on request). The foot levers are made of thermoPlastic. Foot switch with safety catch and manual release: Actuation of the pedal up to the pressure point: The working contact is closed, the working process is initiated. In an emergency situation, actuation beyond the resistance of the pressure point: The working contact is interrupted and locked, the working process is interrupted. Even if the pedal is not actuated, the lock remains in the OFF position in this phase. This reliably prevents an uncontrolled restart or a new start of moving machine parts. Unlocking: Only after the hazardous situation has been eliminated does manual unlocking (push button on the side of the housing) release the Contacts again. The work process can be restarted by pressing the pedal to the pressure point.
Downloads
Product Specifications
Manufacturer | Bernstein |
IP Rating | IP65 |
Entry Type | 2 x M20 |
Number of Pedals | 3 |
Pedal 1 Contact | 1NO 3NC |
Pedal 1 Contact Type | Snap |
Pedal 1 Stages | 3 Stage |
Pedal 2 Contact | 2NO 2NC |
Pedal 2 Stages | Dual |
Pedal 3 Contact | 1NO 3NC |
Pedal 3 Stages | 3 Stage |
Protective Cover | No |
Manual Reset | Yes |
Safety Type | Safety Lock Plus Manual Release |
Pressure Point | 200N x 2 30N x 1 |